175mm Galvanised Brick Reinforcement Coil 20m

URN: 7002010
£26.50ex. VAT
£26.50ex. VAT

Galvanised steel coil for strengthening brickwork and reducing cracking. Suitable for cavity walls and masonry joints. 175mm width offers extra coverage for thick masonry walls or multi-leaf structures.

Nationwide Delivery

Wed 5 Nov

Order by 2pm tomorrow
  • 16hrs
  • 1mins
  • 16secs

Delivery & Returns Info

Make 3 payments of £8.83 with PayPal Learn more
Make 3 payments of £8.83 with Klarna Learn more
Make 4 payments of £6.63 with Clearpay Learn more

Product Overview

Galvanised steel coil for strengthening brickwork and reducing cracking. Suitable for cavity walls and masonry joints. 175mm width offers extra coverage for thick masonry walls or multi-leaf structures.

URN: 7002010
£26.50ex. VAT

Delivery & Returns Information

How Our Delivery Works

We work with a nationwide network of trusted suppliers. As a result, items in your basket may be supplied by different suppliers and delivered separately. Where this applies, you'll see multiple delivery charges at checkout. We always aim to group products from the same supplier to keep delivery costs as low as possible.

Delivery Areas & Charges

Delivery charges listed on our website apply to mainland UK, excluding the following postcode areas: AB, CF, DD, DG, FK, KW, IV, LA, LD, LL, NP, PA, PH, SA, SY
If your delivery address falls within one of these postcode areas, we’ll be in touch before processing your order to confirm any additional delivery costs.
Please note: We do not currently offer delivery outside the UK mainland.

Standard (Nationwide) Delivery

Timber & Sheet, Building Materials, Joinery and Gardens & Landscaping Products
ORDER VALUE DELIVERY CHARGE
Under £300 £10 ex. VAT
Over £300 ex. VAT FREE
Insulation, Plasterboard and Drylining Products
ORDER VALUE DELIVERY CHARGE
Under £350 £35 ex. VAT
Over £350 ex. VAT FREE
Screws & Fixings and Adhesives & Sealants
ORDER VALUE DELIVERY CHARGE
Under £50 £5 ex. VAT
Over £50 ex. VAT FREE

Express Delivery

Express Delivery - Insulation and Plasterboard & Drylining
ORDER VALUE DELIVERY CHARGE
Under £400 £50 ex. VAT
Over £400 ex. VAT £35 ex. VAT
Express Delivery - Timber & Sheet, Building Materials, Joinery and Gardens & Landscaping Products
ORDER VALUE DELIVERY CHARGE
Under £300 £50 ex. VAT
Over £300 ex. VAT £35 ex. VAT

View Full Delivery Policy

Returns

We offer a 30 day returns policy on any faulty products.

View Full Returns Policy


Key Features

  • {{window}} Reinforces above doors and windows
  • {{fitness_center}} Delivers tensile strength across mortar joints
  • {{shield}} Manufactured from cold-formed, zinc-coated steel
  • {{content_cut}} Cuts cleanly with snips or shears

Technical Specification

Technical Specification
Material Type:Galvanised Steel
Width:175mm
Length:20m
Sales Unit:Each

Product Overview

Galvanised brick reinforcement coil with a 175mm width and 20m length. Manufactured from cold-formed, zinc-coated steel, this coil provides continuous bed-joint reinforcement in brick and block masonry. 

It delivers tensile strength across mortar joints, reducing the risk of cracking caused by shrinkage, settlement, or thermal movement. The coil unrolls cleanly and lies flat within a standard 10mm mortar bed, ensuring precise alignment without curl or distortion.

The galvanised coating offers dependable corrosion resistance, making it suitable for internal and sheltered external use. For structures in exposed or marine environments, stainless steel reinforcement is recommended.

Compatible with all common masonry units and mortar types, the coil is a practical solution for strengthening walls at openings, junctions, or areas of concentrated stress. By spreading loads evenly through the joint, it maintains structural integrity and preserves the visual continuity of the brickwork.

The 175mm width suits walls of around 215mm thickness (e.g. full block or solid wall construction), maintaining 20mm mortar cover to both faces for secure embedment and lasting performance.

Features & Benefits

  • Tensile control in bed joints: Increases horizontal tensile capacity to resist cracking from shrinkage and thermal movement.
  • Galvanised protection: Zinc coating safeguards against corrosion in internal and low-exposure conditions.
  • Continuous roll format: 20m coil reduces joints, waste, and installation time on extended runs.
  • Easy to cut and form: Cuts cleanly with snips or shears; lays true without distortion.
  • Compatible with common mortars: Works with cement-lime and masonry cement mixes at 10mm bed thickness.
  • Consistent edge cover: Ensures a minimum of 20mm mortar cover on both faces for full embedment.
  • Defined width: 175mm width suited to 215mm wall thickness while maintaining correct mortar cover to both faces.


Applications

  • Crack control at openings: Reinforces above doors and windows to reduce horizontal cracking.
  • Movement management in long runs: Maintains tensile continuity across extended wall sections.
  • Junction reinforcement: Strengthens returns, partitions, and intersections within bed joints.
  • Local reinforcement: Supports areas around chases, service penetrations, or concentrated loads.


Installation Guidance

  • Prepare the bed: Lay a full, even 10mm mortar bed; ensure surfaces are clean and well supported.
  • Position centrally: Position the coil mid-depth within the mortar bed, ensuring not less than 20mm cover to each face in walls of around 215mm thickness.
  • Maintain laps: Overlap successive lengths by at least 225mm; stagger laps between alternate courses.
  • Discontinue at movement joints: Terminate reinforcement at vertical movement joints, anchoring to one side only.
  • Cut safely: Use snips or shears and wear gloves and eye protection.
  • Reinstate cover: Fully embed reinforcement; avoid exposure at edges or perpend joints.


Compliance & Performance

  • Material specification: Cold-formed galvanised steel strip for masonry bed-joint reinforcement.
  • Corrosion resistance: Suitable for internal and sheltered environments; use stainless steel for severe exposure.
  • Design coordination: Detail in accordance with masonry design standards ensuring correct cover and lap length.
  • Handling and storage: Keep dry and off the ground before installation.
  • Important note: Verify coil width against wall leaf thickness to maintain ≥20mm cover; insufficient cover may compromise corrosion protection.



Related Articles